top of page

Sheet metal pad type thermocouple_R990 series_R991, R992

Type: R991, R992

 

Service intended

 

Normally, when it comes to install thermocouple for measuring temperature on the surface of boiler or heat-exchanger, commonly used method was welding them with high temperature by attaching a metal plate or kinfe-edge type pad which has its thickness over 3 mm.

 

This procedure can only be applied if the tube has the enough strength to endure high temperature welding process. However, this welding precess can't be performed if the tubes are filled with water or oil inside because it may cause the damage to the tube and breakage of thermal-capacity, response time will be delayed and be difficult to measure exact temperature changes.

 

To overcome these issues, R990 series are suitable for performing resistant welding by using spot-welding machine with under 3.2 mm O.D sheath and sheet metal pad, therefore, user can tightly install the pad along the curved surface of the tube, even if the user is not an expert welding operator.

 

Furthermore, due to its compact size and low thermal-capacity, R990 series can offer fast response time without delay even if the measuring temperature fluctuates. Most of all, since R990 series does not cause any thermal-effect, it can be installed on the tubes which carry water or oil inside without expecting any damages to the tube or welded area.

 

Standard features

 

Application

 

■ Boiler tube skin temperature
■ Heater tube and heater exchangers tube skin temperature
■ Other various tube wall temperature measurement

 

Element type

 

K, E, J, T, N

 

Accuracy

 

Standard : 0.75 % (for reading temp.)
Special : 0.4 % (for reading temp.)

 

Sheath outer diameters

 

1.0, 1.6 ,3.2 and 4.8 mm
(*Double element is not 1.0 and 1.6 mm sheath outer diameter)
3.2 mm (Standard)

 

Pad and clip material

 

316L SS

 

 

Download:  CATALOG 

Sheet metal pad type thermocouple_R990 series_R991, R992

    bottom of page