top of page

Integral flow orifice assembly_F510

Type: F510

 

Description

 

Integral orifice primary element utilizes a self centering orifice plate design to eliminate installation error. Enables highly accurate flow measurement in small line sizes. Available with a variety of process connections. Available in ½" to 1½" (15 ~ 40 mm) line sizes.

 

Principle

 

● Improves accuracy and repeatability
● Self-centering plate design eliminates installation errors that are magnified in small line sizes
● Installation flexibility with numerous process connections

 

 

Specification

 

Line size

 

½"(15) ~ 1½"(40)
● Maximum working pressure : 
   Pressure retention per ANSI B16.5 1500Lb

 

Orifice plate

 

316SS / 316L SS and Other

 

Body

 

CF8, CF8M, CF3M, Material per ASTM A351

 

Pipe material (If applicable)

 

A312 Gr 316SS / 316L SS and Other 

 

Flange

 

A182 F304 and Other
● Flange pressure limits are per ANSI B16.5
   Flange face finish per ANSI B16.5, 125 to 250 AARH

 

Body bolts / Studs

 

ASTM A 193 Gr B8 studs and Other

 

Gaskets

 

Glass filled PTFE or Graphite

 

Orifice type

 

Square edge-orifice bore sizes

 

Transmitter connections

 

2⅛" (54 mm) center to center.
Other transmitter spacing can be accommodated using the optional remote adapters and customer supplied impulse piping.
DIN 19213 connections are available.

 

Note

 

Integral orifice bodies contain corner tapped pressure
ports.

 

 

Download:  CATALOG 

Integral flow orifice assembly_F510

    bottom of page