top of page

Explosion proof Thermocouple and resistance temperature detector_R940 series (ETR series)_R941, R942, R943, R944

Type: R940

 

Service intended

 

Measuring the temperature in the area where combustible gas, particles and flammable liquid exist can be a very dangerous task. The electrical energy of measuring instrument is lower than electric motor, however, the malfunction of the instrument or the accident can cause to start the explosion.

 

Therefore, ETR series is explosion proof type product which is designed to be used in a critical danger Zone 1 by acquiring IECEx and ATEX certification.

 

Certificates

 

ATEX II 2G Ex d IIC T6 Gb
IECEx Ex d IIC T6 Gb

 

Ambient temperature

 

-40 ~ +65 ºC

 

Degree of protection

 

EN60529/IEC529/IP67

 

 

Standard features

 

Element

 

■ Sheath type
Thermocouple : K, E, J, T, N
RTD : Pt 100 Ω at 0 ℃
■ Non-metallic protection tube type
Type R (87 % Pt, 13 % Rh/Pt)
Type S (90 % Pt, 10 % Rh/Pt)
Type B (70 % Pt, 30 % Rh / 94 % Pt, 6 % Rh)
Type K

 

Head material

 

ALDC (Standard) 316SS

 

Tolerances on temperature reading

 

■ Sheath type
 - Thermocouple
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230, E988, ISA-MC96.1)
- R.T.D.
Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
■ Non-metallic protection tube type
"K" type : Class 2 (0.75 %)
               Standard (0.75 %)
"R", "S" type : Class 2 (0.25 %)
                     Standard (0.5 %)
"B" type : Class 3 (0.5 %)
               Standard (0.5 %)

 

 

Download:  CATALOG 

Explosion proof TC RTD R940 series (ETR series)_R941, R942, R943, R944

    bottom of page